55
CHECKING
MAGNETO
COILS
Use
a
SUZUKI
pocket
tester
or
an
ohm
meter
and
check
each
coils
for
continuity.
Pocket
tester
09900-25002
|
*
CDI
type
(NIPPON
DENSO)
[
Coil
Resistance
|
Highspeed
(B
-
B/R)
|
Approx.
270
Low
speed
(B/R
R/B)
|
Approx.
2002
|
Charging
(G/W
-
Ground)
|
Approx.
0.29
|
Lighting
(Y
Ground)
Approx.
0.32
*
CDI
type
(KOKUSAN)
Coil
Exciter
(B/R
B/W)
[
Pulser
(B/R
RW)
Approx.
242
Charging
(G/W
Y)
~
Approx.
0.22
Lighting
(Y
Ground)
Approx.
0.32
—]
|
Resistance
Approx.
2102
*
Point
type
(E-24
and
E-35)
[coil
|
Resistance
|
Primary
(B/Y
Ground)
|
Approx.
0.19
Charging
(М/А
Ground)|
Approx.
0.22
|
Lighting
(УЛУ
Ground)
|
Approx.
0.30
*
Point
type
(for
other)
Coil
Resistance
|
Primary
(В/У
Ground)
|
Approx.
0.050
|
Charging
(М/Н
Ground)|
Approx.
0.20
|
Lighting
(Y/W
Ground)
|
Approx.
0.29.
CONDENSER(For
point
type)
A
condenser
is
connected
parallel
with
the
contact
points
to
minimize
point
arking.
The
amount
of
charge
the
condenser
can
store
is
determined
by
its
capacity.
The
capacity
should
be
checked
using
an
electro
tester.
*
Insert
insulation
between
the
points
and
the
condenser
body
should
be
isolated
from
ground.
©
Set
the
tester
selector
knob
to
"MF".
©
Set
the
power
switch
to
“ON”
and
calibrate
the
multimeter
“D”
scale
to
the
“CAL”
posi
tion
using
the
"MF"
calibration
screw.
*
Connect
the
red
(positive)
lead
to
the
con.
denser
lead
and
the
black
(negative)
lead
to
the
condenser
case
mounting
tab.
©
Press
the
test
button
and
note
the
"D"
scale
reading.
If
the
reading
does
not
fall
within
the
stan.
dard
range,
replace
the
condenser.
Electro
tester
09900-28106
STD
condensor
capacity
range
1
NIPPON
DENSO
таке
[0.18
+
0.02uF
`
KOKUSAN
DENKI
make
|
0.25
+
0.03yF