POWER CONTROL SYSTEM FAULTS
3.8 Common Fault Table
Fault Possible Cause Proposed Fix
No 230 volt
output from PSU
Connecting lead between
the site and Leisure Vehicle
not connected
Check and connect lead as per 2.4C
RCD switched off Reset RCD as per 2.4D
RCD not operating correctly Check supply polarity; if the RCD
continues to fail contact your Dealer as
there is probably an equipment or wiring
fault.
MCB switched off Reset MCB by switching OFF (down
position) then back ON (up position), if the
MCB continues to fail contact your Dealer
as there is probably an equipment or
wiring fault.
No or deficient supply
from site
Contact site Warden for assistance
Other fault Contact your Dealer
Reverse Polarity
light is illuminated
on PSU
Mains Supply reversed? The reverse polarity light is designed
to illuminate when the Live and Neutral
supply has been reversed / crossed
over. If the light illuminates there is a
problem with the site supply or the cable
connecting the supply to your vehicle. The
light is designed to work on UK electrical
supplies (where the neutral conductor is
connected to earth at the sub station).
If you are using your vehicle outside the
UK this light may illuminate when no fault
exists. In these cases consult the site
warden for advice.