EasyManua.ls Logo

SwitchDoc Labs WeatherRack2 - Page 17

SwitchDoc Labs WeatherRack2
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21 Page
Version 1.3 October 2020
Data Descriptions:
time: Time of Message Reception
model: SwitchDoc Labs FT020T AIO
device: Serial Number of the sensor - changed on powerup but can be used to discriminate from other
similar sensors in the area
batterylow: 0 if battery good, 1 if battery is getting low
avewindspeed: Average Wind Speed in m/s *10
gustwindspeed: Last Gust Speed in m/s *10
winddirection: Wind Direction in degrees from 0-359.
cumulativerain: Total rain since last reset or power off. in mm.*10
temperature: outside temperature in F with 400 offset and *10 T = (value-400)/10.0
humidity: Relative Humidity in %. light:
Visible Sunlight in lux. uv: UV Index * 10 (meaning an uv index of 0.8 is in the example message above)
Temperature and Humidity Error Conditions
If the humidity level in Hex is 0xFF, this is an error
If the temperature level in Hex is 0x0FFF, this is an error
Clearly those are errors. Here are three more Errors from the temperature:
Valid range for temperature: (with 400 offset added)
-40.0F to 140.0F
Invalid value: 0X7FA
Below minimum: 0X7FC
Above maximum: 0X7FD
Valid Range for Humidity 10% -100%
Errors for Humidity:
Invalid humidity: 0x7A