6 A+ SLO+ Data+
7 B- B V (B)
8 B+
9 I- I U (A)
10 I+
* To use ABI/ABZ with TTL please ensure that your Encoder is capable to sink 5 mA to GND when the
output of the encoder is 0
Attention
** Our upcoming version Drive 400/1000/2000 E1 will support Half-Duplex communication on
this connector instead of HALL. To ensure your configuration will work with future versions of
this drive, please use connector 2 instead for current development.
*** This is a 5 V supply that can provide up to 250 mA for external use.
The supply is protected against short to ground and keeps the current below 400 mA in a continuous
short.
1.3.3.3 Encoder Port 2
Pin # ABI/ABZ (RS422) ABI/ABZ (TTL)* HALL (TTL) BiSS
(RS422)
SSI (RS422)
1 MA- Clock-
2 5 V ** 5 V ** 5 V ** 5 V ** 5 V **
Hardware Manuals / SOMANET Node / SOMANET Node rev.
D.3/D.4
© 2020 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.2.0 | Build: 2020-10-02 14/27

Other manuals for SYNAPTICON SOMANET Node 400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SYNAPTICON SOMANET Node 400 and is the answer not in the manual?

SYNAPTICON SOMANET Node 400 Specifications

General IconGeneral
BrandSYNAPTICON
ModelSOMANET Node 400
CategoryServo Drives
LanguageEnglish

Related product manuals