BeamDriveTroubleshooting
Intheeventthatthebeamdriveshouldfail,takethefollowingstepstodeterminethesourceof
thefailure:
1. Determinewhetherthemotorismoving.Removethelampheadcovers.Havesomeone
powerthelampheadwhileyoumonitorthecalibrationoftheassembly.
2. Iftheassemblydoesnotmoveatalltryreplacingthebeamdriverboard.
3. Ifreplacingthebeamdriverboarddoesnotsolvetheproblem,replacetheskid.
4. Ifreplacingtheskiddoesnotsolvetheproblemreplacethemotor.
52