1.0 Specification
Display 5 digit LED, 10mm character height. Programmable for 0, 1, 2 or 3 decimal
points. Range +99999 / -9999 Least significant digit can be set to count in steps
of 1,2,5 or 10
Load cell input Direct connection of up to 4 x 350R load cells. An internal amplifier feeds this
signal into a 24bit ADC which takes up to 120 readings/sec.
Calibration Simple auto calibration facility using a known weight. Settings stored on non-
volatile memory.
Relays 2 relays rated 1A, 120VAC/24VDC. Can be configured to latch. Relay status
indicators on front panel. Where relays are connected to a contactor or another
relay, the coil of the contactor/relay should have a suppressor fitted.
Analogue out Set as 0-5V, 0-10V, 4-20mA, 0-20mA or 0-24mA. Resolution16 bits
Comms. RS232. Baud rates 2400, 9600, 38k4 & 115k2 selectable. Format is 8 data bits, 1
stop bit and no parity. Can be linked to a printer or a remote display. A ticket
printout can be produced including a title, reference number and reading with
units. With the real time clock option the ticket can also include time & date.
Because the functions are built in, any standard printer can be used. An RS485
option is also available for use with an SY485 adaptor.
Power AC version
90 - 264V AC 47 - 63Hz
DC version
7 - 30V DC. Consumption < 5W.
Case 72mm square DIN43700 panel mounting. Black glass filled Noryl. Depth behind
panel - 86mm (inc. terminals).
Overall size 72 x 72 x 93mm.
E.M.C. Tested to BS EN 61000-4-21:2011 for emissions & immunity.