EasyManua.ls Logo

SystemAir EX Series

SystemAir EX Series
107 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.7 DVEX roof fans series
5.7.1 Types
DVEX 315D4 DVEX 500D6
DVEX 355D4 DVEX 560D6
DVEX 400D4 DVEX 630D6
DVEX 450D4
5.7.2 Description
Integrated thermo-contacts (PTC)
Ignition protection class “Ex e” (increased safety)
Motor protection by posistor in combination with a suitable motor protection device with EC test type certication
Voltage-variable external rotor with nished wire
Installation of sound absorbers possible.
The radial rotor of the vertical blow-out DVEX roof fans has backward-bent rotor blades. Its housing comprises saltwa-
ter-proof aluminium. The base frame and an integrated bird-protection grid are on powder-coated, galvanised sheet
steel, the admission nozzle of copper.
The fans can be used for temperature classes T1, T2 and T3. They convey explosion-capable gases in Zone 1 and Zone 2
as well as groups IIA and IIB.
1
2
3
4
5
6
Fig. 7: Fans of the DVEX series with accessories
Legend
1 FTG Hinged frame 4 ASS-EX Flexible connection
2 TDA Adapter frame 5 ASF Intake connection
3 VKS-EX Self-acting covering cap 6 FDS Flat roof base
53
Ex-fans - 10.2014

Table of Contents

Related product manuals