Installation, Operation and Maintenance instruction EN
K Circular duct fan AC/EC
KV Circular duct fan for wall AC/EC
Prio Circular duct fan AC/EC

Table of Contents

Questions and Answers

  • L
    lewislindseyAug 5, 2025
    What to do if SystemAir Fan air output is not sufficient?
    • K
      Keith LunaAug 6, 2025
      If the air output of your SystemAir Fan is not sufficient, consider these possible causes and solutions: * Ensure the fan impeller turns in the correct direction by verifying the electrical connection. * Check that the electrical connection matches the wiring diagrams. * Adjust the airflow shutters to ensure they are fully open. * Remove any blockage in the air inlet or duct system. * Confirm the product is suitable for the installation location. * For EC motors, check the ambient temperature and ensure sufficient space around the motor for cooling. If the air pressure is too low, make necessary changes to the duct system and installed components to increase it.
  • G
    Gina RushAug 10, 2025
    Why SystemAir K 160 XL sileo Fan motor does not rotate?
    • K
      Kristen PearsonAug 10, 2025
      If the motor of your SystemAir Fan does not rotate, it could be due to several reasons: * A component in the power supply might be defective; check the power supply, replace any defective components, and reconnect it. * The electrical connection may be incorrect; ensure it agrees with the wiring diagrams. * The motor protection might be released due to overheating; let the motor cool, reset the motor protection, and identify the cause of overheating. * A phase loss might have occurred; if it's a 3-phase motor, ensure no phase is missing.
  • S
    Samantha MoranAug 14, 2025
    How to fix unusual noise when SystemAir Fan starts or operates?
    • G
      Gwendolyn RodriguezAug 14, 2025
      If there is unusual noise when your SystemAir Fan starts or operates, it might be due to strain in the duct system connections. To resolve this, loosen the connections, correctly align the parts of the duct system, and then tighten the connections.
  • C
    Caitlin GomezAug 18, 2025
    What to do if SystemAir Fan does not operate smoothly?
    • P
      Patrick MonroeAug 19, 2025
      If your SystemAir Fan does not operate smoothly, consider the following: * Ensure the electrical connection is correct so that the fan impeller turns in the correct direction. * Clean the fan impeller carefully if there is dirt on it. * If the fan impeller has deformations because of too high temperatures: * Replace the fan impeller. * Make sure that the temperature of the transported air is not higher than the value on the name plate. * Ensure the product is correctly installed and check the duct system if there are unusually strong vibrations in the product or the duct system. * Increase or decrease the fan speed until the product operates smoothly if it is operated in a resonant frequency range.
  • L
    Louis HoustonAug 22, 2025
    Why is SystemAir K 160 XL sileo electronic components or the motor overheated?
    • D
      Debra FloresAug 23, 2025
      If the electronic components or the motor of your SystemAir Fan is overheated, it could be due to: * Motor overload or high ambient temperature. Let the motor cool, reset the motor protection, and find the cause of the overheating. * Insufficient cooling. Ensure adequate space around the motor for cooling. * The product is not applicable for the installation location.
  • T
    Tami GarrettAug 27, 2025
    What to do if SystemAir Fan speed does not get the nominal value?
    • W
      warrentrujilloAug 27, 2025
      If the fan speed of your SystemAir Fan does not reach the nominal value, consider these possible causes: * Defective motor winding: If possible, measure the resistance to check the motor winding. * Incorrect speed control setting: Set the speed control correctly. * Mechanical blockage: Remove any blockage preventing the fan impeller from turning freely. * Phase loss: If it is a 3-phase motor, ensure that no phase is missing.
  • K
    Katherine ParkerAug 31, 2025
    What causes SystemAir Fan thermal contacts, PTC or resistors to be released?
    • D
      David KingAug 31, 2025
      If thermal contacts, PTC, or resistors are released in your SystemAir Fan, it could be due to several reasons: * Ensure the fan impeller turns in the correct direction by verifying the electrical connection. * If the motor is a 3-phase motor, make sure that no phase is missing. * The motor may be overheated. Check the motor cooling impeller, and if possible, measure the resistance to check the motor winding. * The capacitor may not be connected correctly. Connect the capacitor correctly, referring to the included motor wiring diagram. Note: This is not applicable for EC motors or 3–phase AC motors.

Summary

Systemair Fan Installation, Operation, and Maintenance

2 Safety

2.2 Safety Instructions

Provides critical warnings and precautions to be followed before working on the product.

2.3 Personal Protective Equipment

4 Installation

4.1 To do before the installation of the product

Lists essential checks and preparations required before proceeding with product installation.

4.2 To install the K fans

Describes the process of mounting the K fans using the included bracket or alternative methods.

4.3 To install the KV fans

4.4 To install the prio fans

Details the method for installing prio fans using pendulum bars or wires in the ceiling.

4.5 To connect the ducts to the product

Provides instructions on how to attach the air ducts to both sides of the fan product.

5 Electrical connection

5.1 To do before the electrical connection

Lists essential checks to ensure correct electrical connection and environmental readiness.

5.2 To connect the product to the power supply

Guides on completing the motor's electrical connection, including safety requirements for earthing and circuit breakers.

5.3 Speed controller for EC motors

Explains how EC motors are controlled via a 0-10V signal and the use of external speed controllers.

5.4 Motor protection for EC motors

Details the integrated motor protection for EC motors and how to reset it.

5.5 Speed controller for AC motors

Notes the variety of speed controllers for AC motors and the importance of compatibility.

5.6 To install motor protection for AC motors

6 Commissioning

6.1 To do before the commissioning

Lists pre-commissioning checks covering installation, connections, safety devices, and blockages.

7.1 To start a product with an EC motor

8 Maintenance

9 Troubleshooting

12 Technical data

12.2.2 Product dimensions for KV fans

12.3 Wiring diagrams

12.3.2 Wiring diagrams for EC fans

12.3.4 Wiring diagrams for speed controllers for EC motors

SystemAir K 160 XL sileo Specifications

General IconGeneral
Voltage230 V
Frequency50 Hz
Airflow418 m³/h
Weight3.1 kg
Enclosure classIP44
Duct connection160 mm
Sound Pressure Level32 dB(A)
Diameter160 mm
Phase1~