3.2.2 DC voltage
- Minimal input current 0.001V DC
- Maximal input current:600V DC
3.2.3 AC voltage
- Maximal input current:600V AC (valid value)
- Frequency range:45 ~ 65Hz
3.2.4 Frequency
3.2.4.1 Frequency measurement for the current through clamp head:
- Measurement range:40Hz ~ 1000Hz
- Input signal range:≥ 0.2A AC current(valid value)
3.2.4.2 Frequency measurement for voltage through Input Jack:
- Measurement range:40Hz ~ 1000Hz
- Input signal range:≥ 0.8V AC voltage (valid value)
Measuring range
6V
60V
600V
Resolution
0.001V
0.01V
0.1V
Accuracy
±(0.5% Reading + +3 digits)
Measuring range
6V
60V
600V
Resolution
0.001V
0.01V
0.1V
Accuracy
±(0.8% Reading + +5 digits)
Measuring range
60.0Hz
1000Hz
Resolution
0.1Hz
1Hz
Accuracy
±(1.0% reading + 5digits)
Measuring range
60.0Hz
1000Hz
Resolution
0.1Hz
1Hz
Accuracy
±(1.0% reading + 5digits)