4.5 Voltage Chart
Test conditions:
typical DC voltages measured with Fluke 77 DVM
supply voltage 13.8V at socket
transmitter unkeyed
allow ±20% for spread of transistor characteristics.
Device Emitter Base Collector
Q1
Q3
Q4
Q6
Q7
Q11
Q13
Q15
Q16
0.0V
0.0V
0.0V
0.0V
0.0V
1.8V
0.0V
13.0V
13.8V
0.0V
0.0V
0.0V
0.0V
0.0V
2.2V
0.0V
13.6V
13.6V
13.0V
13.8V
13.8V
13.8V
13.8V
5.9V
5.9V
13.6V
13.0V