TM8100/TM8200 Service Manual Receiver Fault Finding 255
© Tait Electronics Limited November 2007
10.3 Moderate or Slight Loss of Sensitivity
Introduction This section covers the case where the receiver has suffered a moderate or 
slight loss of sensitivity. As measured in Task 1, the receiver gain will be less 
than 500 000, but not as low as 1500. With a gain less than 40 000, the loss 
of sensitivity will be moderate — about 15dBm too low; otherwise it will 
be slight — just a few decibels too low. There are three tasks:
■ Task 7: front-end calibration and tuning voltages (all bands except K5)
■ Task 8: moderately low receiver sensitivity
■ Task 9: slightly low receiver sensitivity
The fault-diagnosis procedures of Task 8 and Task 9 are similar; although 
the differences are minor they are important.
Task 7  —
Front-end 
Calibration
and Tuning Voltages 
(all bands except 
K5)
If the loss of sensitivity is moderate or slight, the fault is probably in the 
front-end tuning circuitry. This task is for all bands except K5. For the K5 
band, go to Tas k 8
 on page 256.
1. Using the calibration application, check the calibration of the front-
end tuning circuitry: Open the “Raw Data” page and click the 
“Receiver” tab.
2. Record the values listed in the “Rx FE Tune BPF Settings” field — these 
are the DAC values of the FE (front-end) tuning voltages for the five 
frequencies FE TUNE0 to FE TUNE4.
(FE TUNE0 is the lowest frequency and FE TUNE4 the highest fre-
quency in the radio’s frequency band; the values are given in 
Table 10.2.)
3. For each of the frequencies FE TUNE0 to FE TUNE4 in turn, carry out 
the following procedure: Enter the CCTM command 101 aa0, 
where a is the frequency in hertz.
Enter the CCTM command 376 and record the value returned — this 
is the in millivolts.
4. Compare the values measured in Step 2 and Step 3 with the nominal 
DAC and voltage values listed in Table 10.2.
5. If the DAC and voltage values are correct, go to Step 8. If they are 
not, go to Step 6.
6. Recalibrate the receiver using the calibration application, and check 
the DAC and voltage values again.
7. If the DAC and voltage values are now correct, the fault has been 
rectified; go to “Final Tasks” on page 163. If they are not, go to 
Step 8.
8. Go to Task 8
 if the receiver output level x measured in Task 1 was less 
than 40 000; otherwise go to Tas k 9
.