EasyManua.ls Logo

TAJIMA TMBR-SC - Page 241

TAJIMA TMBR-SC
281 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
What to do when the machine stopped
225
Chapter 9
1
2
3
4
5
6
7
8
9
10
11
TP02
3C1
Contact error of the bar switch or start/stop switch,
breakage of the switch harness, or bad connection
of the connector
Check the connector and the connecting terminal.
Replace the limit switch/switch assembly.
3D6
There is abnormality in the program or in the CPU
card.
Check the CPU card.
The software is not installed normally. Install the software.
3DB System RAM insufficient capacity
Turn "OFF/ON" the power.
Replace CPU card.
3DC Memory device error
Turn "OFF/ON" the power. Install the software.
Replace the DOM or CPU card.
3DD System installation error
Install the software.
Replace DOM or CPU card.
3DE External memory device error
Turn "OFF/ON" the power.
Check/replace the USB memory, or replace the
CPU card.
6D1 File error of frame drive parameter Install the software.
6D2 Disconnection of communication line
Turn "OFF/ON" the power.
Check harness connection between CPU card and
USB hub.
Check and/or replace power supply card.
Check and/or replace DC power supply.
Install the software again.
6D3
Disconnection of USB communication line in I/O
card, communication error
Turn "OFF/ON" the power.
Check connection of USB cable
Check and/or replace power supply card.
Check and/or replace DC power supply.
Install the software again.
No. Stop factor How to restore

Related product manuals