Fig. 18
NOTE
Lubrication should be applied at 50 hour intervals
and more frequently with heavy use.
Fuel lter (Fig. 19)
Remove the fuel lter from the fuel tank and
thoroughly wash it in solvent. After that, push the
lter into the tank completely.
Fig. 19
NOTE
If the lter is hard due to dust and dirt, replace it.
Cleaning the cylinder ns (Fig. 20)
When leaves get caught between cylinder ns (16),
the engine may overheat, resulting in lower output.
To avoid this, always keep cylinder ns and fan case
clean.
Every 100 operating hours, or once a year (more
often if conditions require), clean ns and external
surfaces of engine of dust, dirt and oil deposits which
can contribute to improper cooling.
16
16
Fig. 20
Cleaning the mu er (Fig. 21)
Remove the mu er and spark arrestor (if so
equipped), and clean out any excess carbon from
the exhaust port or mu er inlet every 100 hours of
operation.
Fig. 21
For long-term storage
Drain all fuel from the fuel tank. Start and let engine
run until it stops. Repair any damage which has
resulted from use. Clean the unit with a clean rag,
or high pressure air hose. Put a few drops of two-
cycle engine oil into the cylinder through the spark
plug hole, and spin the engine over several times
to distribute oil. Cover the unit and store it in a dry
area.
Maintenance schedule
Below you will nd some general maintenance
instructions. For further information please contact
your Tanaka dealer.