LOW BATTERY DETECTION
A red  ashing light in the electronic eye indicates low batteries.
A solid red light in the electronic eye and no water  ow indicates the batteries
are dead.
The user should change new batteries immediately.
POWER SAVING
If the electronic eye (sensor) has not detected object motion within 30 minutes,
the controller will enter its lowest scan period of 1.4 seconds
When object motion is detected, the controller will change the scan period
from 0.4 seconds to 0.7 seconds and change back to 0.4 seconds when the
object removed.
ANTI-INTEFERENCE SYSTEM
Sunlight or other types of lighting may interfere with the distance sensing
range. In this case, the controller will compensate the sensing distance to a
safe range temporarily. The controller will adjust the distance to the normal
range when no interference is detected.