EasyManua.ls Logo

Tascam DA-P1 - Playback System Measurements; Playback Output Level Measurement; Playback Frequency Response Measurement; Playback Distortion Factor Measurement

Tascam DA-P1
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DA-P1
30
1.
Playback
System
Mode
:
PLAY
Test
tape
:
TY-7551
Measurement
points
:
LINE
OUT
Adjustment
Item
Preliminary
Input
Signal
Adjustment
Point
|
Measurement
Method
/
Value
Adjusted
1.
Playback
output
Connection
:
Fig.
6-9
|
РОМ
МОЛ"
Check
only
+6+1
dBV
(10
kQ
load)
level
1
kHz,
0
dB
Filter
:
OUT
2.
Playback
frequency
PGM
NO.“1”
1
kHz
|
Check
only
20
Hz~20
kHz
+0.5
dB
response
PGM
NO.“2”
20
Hz
РСМ
NO.“3”
100
Hz
РОМ
NO.“4”
10
kHz
РСМ
NO.“5”
20
kHz
3.
Playback
distortion
Connection
:
Fig.
6-9
|
PGM
NO.*1"
Check
only
0.008
%
or
less
factor
1
kHz,
0
dB
400
Hz
HPF
:
IN
30
kHz
LPF
:
IN
22
kHz
LPF
:
IN
4,
Playback
S/N
ratio
|
Connection
:
Fig.
6-9
|
PGM
NO."1"
Check
only
Using
PGM
NO."1"
(0dB)
as
a
1
kHz
0
dB
reference,
when
PGM
NO."6"
22
kHz
LPF:IN
РОМ
NO."6"
(-00)
іѕ
played,
the
S/N
ratio
TEC-A
:
IN
should
be
93
dB
or
more.
5.
Playback
channel
Connection
:
Fig.
6-9
|
PGM
NO.“7”
Check
only
When
PGM
NO."7"
(1kHz,
L)
to
separation
1
kHz,
L
R,
PGM
NO.*8"
(10kHz,
L)
to
R,
1
kHz
BPF
:
IN
РОМ
МО.'8"
PGM
NO.“9”
(1kHz,
R)
to
L,
(10
kHz
BPF
:
IN)
10
kHz,
L
and
PGM
NO.*10"
(10kHz,
R)
to
рам
ко.”
L
are
played
back,
the
channel
1
kHz,
R
separation
with
respect
to
the
РОМ
NO.*10"
play
nominal
output
should
be
10
kHz,
R
as
follows
:
|
1
kHz
:85
dB
or
more
|
10
kHz:65
dB
or
more

Other manuals for Tascam DA-P1