30
Squeegee setting for the swingo 3500
If you experience an uneven suction result, the settings of the squeegee should
be corrected. Proceed as follows to do this:
Before carrying out the adjustment, check that:
• the blades are not damaged (replace).
• the suction unit is not damaged.
Height setting (Fig. A)
• Lower the squeegee.
• Pull out the key and apply the parking brake (refer to page 25).
• Unscrew the hexagonal nut.
• Turn the Allen screw left or right.
The distance between the floor and the running wheel (with the blades standing
vertically) must be between 1-3 mm.
• Retighten the hexagonal nut.
• Check the result during the cleaning and refer to angle of inclination (Fig B).
Angle of inclination(Fig. B)
• Switch of the brush drive and the suction unit.
• Pull out the key and apply the parking brake (refer to page 25).
• Unscrew the Allen screws (nos. 1 to 4) on the suction unit adjustment (half a
turn).
• Insert a screw driver into the slot in the cam and hold it in position while
unscrewing the Allen screw No.5.
• Only change the angle of inclination in small steps using the cam.
• Keep the screwdriver in this position while tightening the cylindrical screws
numbers 1 to 5.
• Check the result and correct it again if necessary.
Malfunctions
A correct angle has been achieved when the tip
of the rear blade (x) is distributed over the
complete width of the suction unit.
B
1
2
4
3
5
x
x
1
2
4
3
5
A
Malfunction Possible causes Troubleshooting page
Machine does not
run
Maschine switched off
• Switch on the
keyswitch
24
Battery plug ^
disconnected
• Reconnect the battery
plug to the machine
24
Main fuse defect
• Check/replace the fuse
29
Error code on display
• Call your service
partner
Machine does not
move
Immobiliser
• Sit on the driver seat
Drive pedal activated
when switching on
• Make sure no pressure
is being applied to the
drive pedal, and turn
the keyswitch again
Parking brake on
• Release the parking
brake
25
Batteries not suf-
ficiently charged
Batteries discharged
• Charge batteries
25
Charger or connect-
ing cable defective
• Call your service
partner
Battery defect
• Call your service
partner
Wrong charger type
for batteries
• Check and if
necessary replace
Not able to switch
off brush or suc-
tion unit
Relay defective
• Stop the machine
using the battery
disconnection socket
• Call your service
partner
24
Brush does not
turn
Brush drive switched
off
• Press the brush unit
button
24
Main fuse defect
•Replace fuse
29
Motor runs but not
tool
• Drive belt torn
• Call your service
partner
Poor vacuum
performance
Floor remains
wet
Soiled solution
not picked up
Suction unit not
activated
• Press the suction unit
button
24
Suction hose not
connected
• Connect suction hose
26
Squeegee not on the
floor
• Clean the squeegee
• Check that the
squeegee suspension
is functioning correctly
27
Worn blades
• Replace blades
29
Hose or nozzle
blocked (e.g. by piec-
es of wood or residual
material)
• Remove the blockage
Suction filter blocked
• Remove the blockage
24
Indicator lights up but
suction unit does not
work
• Check fuse and
replace if necessary
• If the fuse is not
defective, call for
technical assistance
29
Squeegee pressure
incorrect
• Re-adjust
30
Suction unit
switched off
Recovery tank full
• Empty the recovery
tank
• Check the battery
indicator
• Check the fuses
27
Full recovery tank
probe soiled
• Check the probe, and
clean if necessary
28