Technical Manual
31. May 2007 Revision: V1.10 5-6
Copyright © 2007, JohnsonDiversey, Inc.
07.0 swingo 450B - software u parameters.fm - 31. May 2007
27 Switching cycles dosing
pump
B2 0 0 1 No
Service inter-
val
28 Service interval E/B1/B2/B3 200 900 450 1 Yes
29 Service hours counter
(Service LED)
E/B1/B2/B3 0 279'620 0 0.1 Yes
Battery moni-
toring
30 Battery reset level fully
charged (maintenance
free)
B1/B2/B3 20 28 25.6 0.05 No
31 Battery reset level partial-
ly charged (maintenance
free)
B1/B2/B3 20 28 24.6 0.05 No
32 Battery 3 LEDs (mainte-
nance free)
B1/B2/B3 20 28 23.8 0.05 No
33 Battery 2 LEDs (mainte-
nance free)
B1/B2/B3 20 28 22.8 0.05 No
34 Battery 1 LED (mainte-
nance free)
B1/B2/B3 20 28 21.8 0.05 No
35 Battery warn level (main-
tenance free)
B1/B2/B3 20 28 21 0.05 No
36 Battery reset level fully
charged (wet)
B1/B2 20 28 25.6 0.05 No
37 Battery reset level partial-
ly charged (wet)
B1/B2 20 28 24.6 0.05 No
38 Battery 3 LEDs (wet) B1/B2 20 28 23.8 0.05 No
Unit Parameter Description Machine
type
Min. Max Default
V2.4
Step size To be pro-
grammed
Table 1: Parameter Software