Technical Manual
31. May 2007 Revision: V1.10 5-9
Copyright © 2007, JohnsonDiversey, Inc.
07.0 swingo 450B - software u parameters.fm - 31. May 2007
5.2.6 Parameter overview
Function / Handling Configbox display
• Switch on machine and press “SELECT”
• Read out machine type and software version
Swingo 450/ 750/ 1250
SW-Version: 2.XX
• Parameter 11-13:
EBU, Battery and Charger
• Press “NEXT” to see the first parameter
11: Brush Lowering
with motor
• Press “SELECT” to change the parameter
• The cursor changes to the second row
11:BrushLowering
with motor
• Press “NEXT” to change the displayed parameter
• Press “SELECT” to program the changed parameter
11:BrushLowering
manually
• Press “NEXT” for the next parameter
• Parameter 16-20: Running hours look like:
• These parameters can only be read out
17:HoursVacMotor
178.3h
• Parameter 28: Service interval setting
• Pressing “NEXT” changes the hours in steps of 50 up to 900 and back to 200
• The value can be set between 200 and 900 hours
• Press “SELECT” to program the value to the board
• Parameter 29: Service hours counter reset:
• Press “SELECT” to reset the hours counter
• The cursor changes to the second row
•Press
• “SELECT” to program the hours to 0
Table 2: Menu guide