OBSTACLE DETECTION
If the obstacle detection function (adjustable through FR trimmer) is activated during an opening ma-
noeuvre, the gate closes approx. 20 cm., if it is activated during a closing manoeuvre, the gate opens
all the way .
WARNING: the control panel logics may interpret mechanical friction as an obstacle.
8. LED DI DIAGNOSI
LED - DL1
Apart from highlighting the presence of the battery, LED DL1 displays any mistakes with a series of
pre-set ashes in various colours:
Key:
led always on; led ashing;
Always on (green):
main voltage present;
1 ash every 4 seconds (green):
no main voltage; power supply through battery/photovoltaic
panel
CheckthemainvoltageandthefuseF2
LED - DL2
The DL2 LED indicates mistakes in the board logic with a series of pre-set ashes in dierent colours:
Attention: certain warnings/errors are signaled in sync with a series of ashes of the ashing light.
Key:
led always on; led ashing; error signaled by the ashing light;
1 ash every 4 seconds
(green):
normal operation;
/ alternate ashing:
(red/green)
saving to be performed;
alternate fast ashing
/ : (green/orange)
Memorization to be carried out of the variation in deceleration
TheboardrecognizesthevariationinpositionoftheRALLtrimmerandsi-
gnalsthememorizationtobecarriedoutinordertolearnthenewdecelera-
tion.PressthePROGkey.(seeparagraph“RALLtrimmer”)
Fast (orange) ashing:
saving in progress;
1 (red) ash:
phototest error
Disablephototest(dip-switch6OFF),checktheoperationofthephotocells
andtheirconnection;
1 (orange) ash:
unknown status, next operation REALIGNMENT;
2 (red) ashes + :
obstacle for motor;
Makesuretherearenoobstaclesacrossthepathofthegateandthatitslides
smoothly;
Withanactiveautomaticclosingfeature,aftertheinterventionmeanttode-
tecttheobstacle,theautomaticclosingisdeactivated.Acommandpulseis
requiredtocarryouttheclosing;
3 (red) ashes + :
no motor encoder signal;
Checkwiring,checkencoderbyTEST-ENCODER(optional);
CheckthecorrectashingofledE1*
4 (red) ashes: + :
no motor signal;
ENGLISH