OPERATING PROCEDURES
6-11
Models 345, 346, 349, 355 NPR
Operating Procedures
6
4. Once the proper brix has been achieved, close the
sampling valve. Install the front drip tray and the
splash shield on the front of the freezer.
Figure 6-41
5. With a pail beneath the door spout, press the
BEATER key. Open the draw valve and drain the
freezing cylinder. Close the draw valve. Press the
PRIME key. This will cause the product to flow to the
mix hopper.
6. Repeat step 1 through step 4 for the remaining
freezing cylinder(s).
7. To place the freezing cylinder in Auto mode, press
the AUTO key. When the machine cycles off, the
product will be at serving viscosity.
Repeat this step for the remaining freezing
cylinder(s).
Figure 6-42
8. Replace the side panels.
90-Day Closing Procedure
We recommend that the machine be completely
disassembled and cleaned at least every 90 days using
the following procedures.
To disassemble a freezer, the following items will be
needed:
• Two cleaning pails
• Cleaning brushes (provided with freezer)
• Cleaner
• Single-service towels
Draining Product from the Freezing
Cylinder
1. Press the BEATER key. This will allow the beater to
operate. Open the draw valve and drain the product
from the machine.
Figure 6-43
ALWAYS FOLLOW LOCAL HEALTH CODES.