EasyManuals Logo

TCL H5P44W User Manual

TCL H5P44W
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
12
Water drainage method
When there is excess water condensation inside the unit, the appliance stops running and shows
”. This indicates that the water condensation needs to be drained using the following
procedures:
Manual Draining
1. Power o and unplug the unit from power source.
2. Place a pan under the lower drain plug.
3. Remove the lower drain plug.
4. Water will drain out and collect in the pan.
5. After the water is drained, replace the lower drain plug firmly.
6. Turn on the unit.
Continuous drainage
When unit is running in Dry mode, you can use the method below for continuous drainage.
1. Power o and unplug the unit from the power source.
2. Remove the drain plug (Fig 1). Be cautious as some residual water may spill during this
setup process.
3. Connect a drain hose (Fig. 2). Note: Drain hose is only included on select models.
4. The water can be continuously drained through the hose into a floor drain or bucket.
5. Turn on the unit.
Garden hose or
drainage hose
1. 2.
Drain
Cap
Note: A standard
garden hose will
work for continuous
draining. Garden hose
is not included.