EasyManua.ls Logo

TCL TAC-07CHSA/VB - Page 33

TCL TAC-07CHSA/VB
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TCL Air Conditioner Service Manual
10.4 Vane does not operate at all.
10.5 Cooling/heating conversion is disable.
Vane bending, structures
interference check
Connector check
(Broken/short circuit/mal-
connection)
Vane motor check
PCB assembly check(vane
motor driving circuit)
Replace the vane motor
Replace the PCB
Heating operation ON by remote
con
troller
Connector check
If the 4-way valve is ON, "tick"
sounds.
PCB assembly
hk
4-way valve connection check
outdoor unit connecting wire check
Check the voltage of 4-way valve
co
il
4-way valve coil resistance check
32