3.2.14 P6---Overheating protection on Cooling mode
On Cooling or Dry mode, when ODU condenser coil temperature OPT≥62 , MCU will switch off outdoor unit and
show P6 failure code.
Display P6
ODU fan motor
works normal?
Replace OPT sensor
Replace ODU PCB
Fan motor
broken?
Replace fan motor
End
No
No
Y
es
Y
es
P6 disappear?
P6 disappear?
Y
es
No
Y
es
No
The sensor open or
short circuit?
No
Y
es
Sensor loosing
from connector?
Re-connect sensor
P6 disappear?
Y
es
Yes