EasyManua.ls Logo

TCL TAC-18CHS - User Manual

TCL TAC-18CHS
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
TAC-09CSC/K TAC-09CHSC/K
WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS
CONTENTS
1. IMPORTANT NOTICE ···································2
2. TECHNICAL SPECIFICATION ·····················3
3. DIMENSIONS ················································8
4. REFRIGERATING CYCLE SYSTEM ············· 9
5. PERFORMANCE CURVES ····························12
6. OPERATION DETAILS ·············16
7. WIRING DIAGRAM ······························23
8. EXPLOSION VIEW ···················29
9. PARTS LIST ·································33
10. ANNEX 1 THERMISTOR CHARACTERISTIC
11. ANNEX 2 GENERAL
12. ANNEX 3 TROUBLE SHOOTING
13. ANNEX 4 R407C REFRIGERANT
Models
TAC-07CS/K TAC-07CHS/K
TAC-09CS/K
TAC-09CHS/K
TAC-12CS/K
TAC-12CHS/K
TAC-24CS/K
TAC-24CHS/K
OB207t-1qxp 25/9/97 8:51 PM Page 1
TCL
14. ANNEX 5 INSTALLATION INSTRUCTION Part 1
SERVICE MANUAL
TAC-07CSC/K TAC-07CHSC/K
TAC-12CSC/K TAC-12CHSC/K
TAC-18CSC/K TAC-18CHSC/K
TAC-24CSC/K TAC-24CHSC/K
No.TE031229
TAC-18CS/K TAC-18CHS/K

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the TCL TAC-18CHS and is the answer not in the manual?

TCL TAC-18CHS Specifications

General IconGeneral
BrandTCL
ModelTAC-18CHS
CategoryAir Conditioner
LanguageEnglish

Summary

IMPORTANT NOTICE

Technical Specifications

Product Dimensions

Refrigerating Cycle System

Heat Pump

Diagram and explanation of the heat pump operational cycle.

Cooling Only

Diagram and explanation of the cooling-only operational cycle.

Wiring Diagram

INDOOR UNIT

Electrical schematic for the indoor unit components and connections.

OUTDOOR UNIT

Electrical schematic for the outdoor unit components and connections.

ANNEX 3 TROUBLE SHOOTING

1. Electric parts

Checks for electrical components, wiring, and power supply issues for diagnosis.

2. Refrigerant system

Troubleshooting steps for refrigerant leaks, pressure, and charge problems.

3. Troubleshooting

Flowcharts for diagnosing and resolving operational failures.

ANNEX 5 INSTALLATION INSTRUCTION

3. Split type installation

Guidelines for selecting suitable locations for indoor and outdoor units.

3.5 Flaring work and connection of piping

Detailed procedure for pipe cutting, burr removal, flaring, and connection.

3.8 Air purging

Steps for removing air and moisture via vacuum pump for system integrity.

3.9 Test running

Procedures for initial operation checks and performance evaluation after installation.