EasyManua.ls Logo

TCM FB10-8 - Page 213

TCM FB10-8
259 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
(7)
205
37
: Drive motor temp. abnormal
Resets when the temperature drops to less than
165°C [329°F].
206
36
: Drive motor temp. too high
Resets when the temperature drops to 145°C
[293°F] or below.
① Turn the key switch OFF and allow the motor to cool
down for at least 30 minutes.
② Check the voltage between CD2D-6 and CD2D-17
on the drive motor inverter unit.
Repair the drive motor or wiring.
③ Replace the drive motor inverter unit.
(8)
207
35
: Drive motor thermosensor defective
AD input range abnormal
Automatically resets when the input returns to
normal.
① Check the drive motor thermosensor for proper
installation.
Install properly.
② Check the voltage between CD2D-6 and CD2D-17
on the drive motor inverter unit.
Repair the drive motor or wiring.
③ Replace the drive motor inverter unit.
(9)
208
89
: Excessive travel inching
Resets when the accelerator output is OFF.
① Check whether the accelerator and brake pedals have
been pressed for 10 seconds or longer.
② Check the voltage between CD2D-8 and CD2D-20
on the drive motor inverter unit.
Repair the accelerator 1 potentiometer or wiring.
③ Check the voltage between CD2D-9 and CD2D-21
on the drive motor inverter unit.
Repair the accelerator 2 potentiometer or wiring.
④ Check the voltage at the CD2D-4 on the drive motor
inverter unit.
Repair the relay unit or wiring.
⑤ Replace the drive motor inverter unit.

Table of Contents