- 65 -
3. TROUBLESHOOTING GUIDE
(8)
: Data reception abnormal
Automatically resets when the input returns to
normal.
① Check the connectors for the CN1E-8, -9, -10,
-11, -12 terminals on the EPS motor controller for
looseness.
Connect securely.
② Check the harness for those connectors.
Correct the wiring.
③ Remove the EPS motor controller connector.
–
④ Check the resistance between CN1E-9 and CN1E-12
on the EPS motor controller.
Repair the EPS motor controller.