CAUTION
e
Make
sure
the
electrolyte
temperature
is
below
40°С
when
starting
charging.
If
not,
wait
until
the
temperature
drops
below
40°С.
elf
the
electrolyte
temperature
exceeds
50°C
while
charging,
the
battery
service
life
will
be
shortened.
Do
not
try
to
charge
the
battery
when
the
ambient
temperature
is
extremely
low.
Charging
in
a
cold
storage
or
outdoors
in
a
cold
region
will
shorten
the
battery
service
life.
|
Frequent
overcharges
or
equalizing
charges
causes
the
battery’s
electrolyte
temperature
to
rise,
and
if
the
electrolyte
temperature
exceeds
50°C,
the
battery
service
life
will
be
shortened.
Use
a
charger
appropriate
for
each
battery
capacity.
Charging
with
an
improper
charger
or
using
a
charger
for
the
other
purposes
will
cause
a
trouble.
e
Do
not
disconnect
the
charger
cable
from
the
power
source
while
charging.
If
the
charger
cable
is
disconnected
by
mistake,
press
the
charge
stop
button
without
fail.
The
load
handling
or
traveling
circuit
won't
function
unless
this
button
is
pressed.
If
the
LCD
won't
operate
when
the
key
switch
is
turned
on
after
finishing
the
charge,
press
the
charge
stop
button.
e
Use
caution
not
to
allow
electrolyte
splash
over
the
truck
body
or
electric
components.
If
they
are
contaminated
with
electrolyte,
contact
your
local
TCM
dealer.

Other manuals for TCM FB20-7

Related product manuals