PLAYBACK
HEAD
AZIMUTH
ADJUSTMENT
PLAYBACK
PERFORMANCE
arf4e—w—[
>]
Q307/308
Qioi/i04
Quo306
yo
2iv
va
MONITOR
Q202/;
23V
7
Q201/204
Fig.
7-2
Simplified
Diagram
-Playback-
Coarse
Adjustment
PWN
E
Connect
a
level
meter
to
either
OUTPUT
jack.
Thread
a
TEAC
test
tape
YIT-1003
on
the
unit.
.
Play
the
15
kHz
test
tone
in
section
2
of
the
test
tape.
Slowly
rotate
the
azimuth
screw
until
maximum
indication
is
obtain
on
the
level
meter.
NOTE
If
during
playback,
a
slight
pressure
on
the
heads
results
in
a
vise
of
the
reading
of
the
level
meter,
head
alignment
ad-
justments
should
be
accomplished.
Fine
Adjustment
CAUTION
After
coarse
adjustment,
do
not
make
large
corrections,
turn
Azimuth
screw
1/4
turn
or
less.
It
is
absolutely
essential
to
accomplish
the
coarse
adjustment
before
using
this
method
to
avoid
phase
errors
larger
than
45°
Connect
the
test
equipment
as
shown
in
Fig.
7-8.
Play
a
10
kHz
signal
and
adjust
the
azimuth
screw
until
the
oscil-
loscope
shows
that
the
signals
are
less
than
45°
in
phase.
Secure
the
screw
with
a
drop
of
LOCTITE.