NOTE
Do
not
disturb
the
specified
input
level
position
of
these
controls
until
the
remaining
checks
and
adjustments
are
completed.
The
difference
between
the
channels
must
not
exceed
2
dB
as
indicated
on
the
level
meter.
If
it is
not
within
limits,
check
the
amplifier
gain,
the
LINE
controls
refer-
ence
marks
should
be
together.
VU
METER
CALIBRATION
-RECORD=-
OO
10.
With
the
same
400
Hz
signal.at
-8
dB
applied
and
the
MONITOR
switch
in
SOURCE,
adjust
VR
303/306
for
0
VU
on
the
VU
meters.