BIAS
ADJUSTMENT
:
NOTE
Adjust
BIAS
trap
(L
302/304)
before
adjusting
BIAS
levels.
NORMAL
Position
UW
woh
Thread
a
record
test
tape
(Scotch
150)
on
the
unit.
Place
BIAS
switch
in
NORMAL
position.
Place
MONITOR
switches
in
TAPE
position.
Apply
a
400
Hz
signal
at
-8
dB
at
the
LINE
IN
jacks.
Adjust
VC
501/503
for
a
peak
on
the
level
meter.
Turn
the
capacitors
clockwise
until
a
decrease
of
0.5
dB
is
obtained.
HIGH
Position
1.
RECORD
LEVEL
SET
1.
2.
3.
Mae
WN
Thread
a
record
test
tape
(Scotch
203)
on
the
unit.
Place
BIAS
switch
to
HIGH
position.
Place
MONITOR
switches
in
TAPE
position.
Apply
a
400
Hz
signal
at
-8
dB.
at
the
LINE
IN
jacks.
Adjust
VC
502/504
for
a
peak
on
the
level
meter.
Turn
the
capacitors
clockwise
until
a
decrease
of
.0.5
dB
is
obtained.
Using
Scotch
203
tape,
BIAS
switch
at
HIGH
position.
Apply
a
400
Hz
signal
at
-8
dB
at
the
LINE
IN
jacks.
OUTPUT
controls
must
be
at
specified
output
level
setting
(-8
dB
at
OUTPUT
jacks).
Place
unit
in
record
mode,
monitor
switches
in
the
SOURCE
position.
.
Adjust
VR
302/305
for
a
reading
of
0
W
on
the
VU
meters.
(-8
dB
at
the
OUTPUT
jacks.)
OVERALL
FREQUENCY
RESPONSE
To
avoid
saturation
of
the
tape
these
checks
should
be
made
at
least
20
dB
below
the
specified
input
level.
Any
bias
signal
feeding
into
the
test
equipment
should
be
filtered
out
by
ad-
justing
the
external
bias
trap.
A
broad
band
VIVM
may
be
used
at
the
output
for
this
adjustment.