TASCAM MD-CD1 RS-232C Protocol Specification
11 TEAC Corporation
AUTO CUE LEVEL PRESET
Sets the Auto Cue Level of the controlled device.
A return command is returned only if Sense [FF] is specified.
The Auto Cue Mode setting is made using the command "AUTO CUE SELECT [30]."
Command 20
Machine ID 0
Data 2 bytes
Data 1 Data 2 Description Remarks
0 0 Preset –24dB
0 1 Preset –30dB
0 2 Preset –36dB
0 3 Preset –42dB
0 4 Preset –48dB
0 5 Preset –54dB
0 6 Preset –60dB
0 7 Preset –66dB
0 8 Preset –72dB
F F Sense Requests that the current preset level be returned.
・ If data other than the above is received, the CD-RW901 will transmit ILLEGAL [F2].
Return AUTO CUE LEVEL RETURN [A0]
AUTO TRACK LEVEL PRESET
Sets the Auto Track Level of the controlled device.
A return command is returned only if Sense [FF] is specified.
The Auto Track Mode setting is made using the command "AUTO TRACK SELECT [31]."
Command 21
Machine ID 0
Data 2 bytes
Data 1 Data 2 Description Remarks
0 0 Preset –24dB
0 1 Preset –30dB
0 2 Preset –36dB
0 3 Preset –42dB
0 4 Preset –48dB
0 5 Preset –54dB
0 6 Preset –60dB
0 7 Preset –66dB
0 8 Preset –72dB
F F Sense Requests that the current preset level be returned.
・ If data other than the above is returned, the CD-RW901 will transmit ILLEGAL [F2].
Return AUTO TRACK LEVEL RETURN [A1]