Fault clearance
Before you look for a fault on the heat meter itself, please check the following items:
Is the heating on? – Is the circulation pump running?
Are the shut-o devices fully open?
Is the pipe free (possibly clean the strainer)?
Is the dimensioning okay?
In case of error F -6, execute the following steps:
1
Check the meter installation.
2
Generate a positive flow.
3
Check the current flow (LCD).
4
Wait until the LCD is o again (approx. 2 mins.).
5
Press the button again.
The result of flow direction recognition is only displayed after 8s.
6
Check LCD as to whether F-6 is now o.
!
If F-6 does not cease, you must replace the meter.
Display levels
The display is switched o under normal operation. Approx. 2 minutes after the last time
a key is pressed, the display is deactivated automatically. The flow rate / temperature
display is always updated every 8s. (When there is no flow rate, the temperature is only
measured every 15 minutes.)
The heat meter has 4 display levels.
A long button push switches between the display levels. A brief button push jumps to the
next display within a level
2
!
In the device number display, the number next to the display identifier is the first