EasyManua.ls Logo

Technics Quartz SL-10 - Page 8

Technics Quartz SL-10
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Notes
and
maintenance
@
Turn
down
amplifier
volume
(preferably
all
the
way)
before
turning
the
stand-by
switch
on
(.=)
or
“()”
(4m).
This
protects
your
ears
and
the
speakers
from
switching
noise.
Make
sure
the
stand-by
switch
is
in
the
“(')"
(41)
position
before
unplugging
or
plugging
in
the
AC
cord.
Auto-return
operation
will
not
occur
if
you
press
the
stand-by
switch
while
a
record
is
being
played.
The
tonearm
will
rise
above
the
record
surface
but
stay
where
it
is.
Therefore,
if
you
then
press
the
switch
again
to
turniton,
the
tonearm
will
go
back
to
the
start
position.
Be
sure
to
remove
all
dirt
and
dust
from
the
stylus
tip.
The
stylus
tip
can
not
retain
proper
groove
contact
when
it
is
dirty.
This
causes
bad
sound
reproduction
and
excess
wear
on
the
stylus
tip
and
grooves.
Therefore,
use
the
accessory
brush
to
remove
dust
and
dirt
by
brushing
up-
ward,
as
shown
in
the
diagram.
Also,
use
a
good
record
cleaner
to
remove
dust
and
dirt
from
the
grooves
@
Wipe
the
display
panel
and
cabinet
with
a
soft,
dry
cloth.
Never
use
any
cleaners
containing
alcohol,
benzine
or
thinner
Use
of
a
chemical
dust
cloth
should
also
be
avoided,
Be
sure
that
the
display
panel
is
not
exposed
to
insecticide
spray
Toremove
stubborn
fingerprints
or
grease
spots,
disconnect
the
AC
power
plug.
Use
a
soft
cloth
slightly
moistened
with
a
mild
soap-and-
water
solution,
Do
not
wipe
the
display
panel
during
play,
or
the
tonearm
may
be
attracted
toward
the
display
panel
due
to
the
gener-
ation
of
static
electricity.
If
there
is
no
record
on
the
turntable
mat,
the
tonearm
will
not
move,
even
if
you
press
the
start
button.
This
unit
uses
an
optical
sensor
to
detect
record
size
and
whether
there
is
a
record
on
the
turntable
mat
or
not.
If
no
record
is
on
the
mat,
the
turntable
will
rotate
once
or
twice
and
the
optical
sensor
will
detect
the
fact
that
no
record
is
present.
Therefore,
the
tonearm
will
not
move.
This
safety
feature
prevents
accidental
damage
to
the
stylus
tip
and
cartridge.
This
also
means
that
if
you
place
a
transparent
record
(which
may
be
coloured
red,
green,
yellow,
blue,
etc.)
on
the
turn-
table
mat
without
using
the
light-block
sheets,
the
turntable
will
operate
as
if
there
was
no
record.
Therefore,
put
the
light-block
sheet
under
the
transparent
record
before
attempting
to
play
it
Use
the
manual
play
procedure
for
records
that
do
not
meet
industry
standard
dimensions.
Always
be
sure
the
cabinet
is
shut
completely.
If
the
cabinet
is
not
locked
shut
completely
on
both
sides,
the
sylus
tip
will
not
maintain
optimum
contact
with
the
record
grooves.
Also,
open
and
shut
the
cabinet
carefully.
Do
not
open
the
upper
cabinet
unless
the
lower
cabinet
is
supported
(when
using
the
unit
upright
or
on
its
side).
Also,
hold
onto
the
upper
cabinet
when
you
open
it
when
using
the
unit
on
its
side
or
upright.
If
the
cabinet
is
allowed
to
open
suddenly,
it
is
dangerous
and
may
cause
damage
Adjust
the
stylus
pressure
in
the
following
cases.
Stylus
pressure
is
normally
set
to
1.25
grams
but
may
be
raised
or
lowered
by
+0.25
grams.
It
may
be
necessary
to
increase
stylus
pressure
when
play-
ing
records
cut
at
high
levels,
or
when
room
temperature
is
low,
or
when
the
unit
easily
picks
up
external
vibrations.
This
will
help
prevent
distortion
and
groove-skipping
To
adjust
stylus
pressure,
turn
either
way,
as
shown
in
the
diagram.
The
screw
is
coupled
to
the
graduated
ring.
Note:
Do
not
turn
the
stylus
pressure
adjustment
screw
further
than
the
set
limits
(1.5
g~1.0
g).
Stylus
pressure
,
4
adjustment
screw
+
1.59
1.25
g
1.0g
-
oo
Replacement
of
cartridge
The
cartridge
supplied
with
this
unit
has
a
precision
polished
elliptical
block
diamond
stylus
tip.
This
will
produce
excellent
sound
quality
for
about
500
hours
of
playing
time
(more
or
less,
depending
on
conditions).
After
that,
it
should
be
replaced
to
prevent
deterioration
of
sound
quality
and
excess
record
wear
Since
this
is
an
MC
cartridge,
the
stylus
itself
cannot
be
re-
moved.
The
entire
cartridge
must
be
replaced.
Ask
for
replace-
ment
cartridge
EPS-310MC,
at
your
Technics
dealer.
=
>
5
Turn
off
the
stand-by
switch.
Open
the
upper
cabinet
all
the
way
Slide
the
arm
lock
over
so
it
locks
the
tonearm
in
place,
as
shown
in
the
diagram.
Use
the
accessory
screwdriver
to
unscrew
the
cartridge.
(As
shown
in
the
diagram,
loosen
the
screw
until
the
car-
tridge
can
be
freely
removed.)
adjustment
screw
.
each
tee
ae
.
Pull
off
the
cartridge.
r
Line
up
the
new
cartridge’s
pins
with
the
tonearm
connector
and
push
the
new
cartridge
securely
onto
the
tonearm.
Then
screw
in
the
screw
Push
the
arm
lock
back
to
its
original
position.
(Play
will
not
take
place
if
the
tonearm
is
locked.)
Note:
Attach
the
cartridge’s
stylus
protector
while
installing
the
new
cartridge
and
be
careful
not
to
touch
the
stylus
itself.

Related product manuals