EasyManuals Logo

Technics SL-P200 Service Manual

Technics SL-P200
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
SL-P200
SS)
i
4
018)
Mi
MEASUREMENTS
AND
ADJUSTMENTS
Caution:
@
It
is
very
dangerous
to
look
at
or
touch
the
laser
beam.
(Laser
radiation
is
invisible.)
With
the
unit
turned
“on”,
laser
radiation
is
emitted
from
the
pickup
lens.
Avoid
exposure
to
the
laser
beam,
especially
when
performing
adjustments.
PLAYER
SETTING
1.
Remove
the
cabinet.
(Refer
to
page
7.)
2.
Remove
the
disc
clamper
and
magnet.
(Refer
to
page
7.)
3.
Remove
the
disc
holder
and
power
switch
rod.
(Refer
to
page
7.)
¢
Setting
of
the
test
disc
(Shown
at
the
right
figure.)
1.
Place
the
test
disc
and
magnet.
2.
Turn
“ON”
the
power
switch
of
the
player,
while
holding
the
levers
of
the
switches
(S101,
S102)
in
the
direction
of
the
arrow.
3.
Release
the
levers
of
the
switches
(S101,
$102)
after
the
test
disc
starts
rotating.
ADJUSTMENT
POINTS
e
Servo
P.C.B.
yy
Z|
ee
rae!
oh
(Focus
offset
adj.)
Vaiog
VR501]
(PLL
adj.)
(Tracking
VR102!
(Tracking
gain
adj.)
balance
adj.)
[vR101]
(Best
eye
adj.)
Main
P.C.B.
LINE
OUT
l
PLL
adjustment
test
point
D158
(+12V)
+“
Connect
the
red
lead
p21
_
of
servo
gain
ajuster.
©
(~12V)
Connect
the
blue
lead
wire
of
servo
gain
adjuster.
e
Filter
for
turntable
height
adjustment
Resistor:
10kQ
(ERDS2TJ
103)
To
oscilloscope
(+)
Capacitor:
0.1pF
(ECQM1H104KV)
To
oscilloscope
(—)
Measuring
Instruments
and
Special
Tools
@
Servo
gain
adjuster
(SZZ2P1017F)
e@
Test
discs
Test
disc
(SZZP1014F)
old
or
new
type
Inspection
test
disc
(SZZP1054C)
Uneven
disc
(SZZP1056C)
Black
band
disc
(SZZP1057C)
Adjustment
Procedure
Step
1:Make
the
temporary
setting
of
each
VR.
(Refer
to
page
13.)
Step
2:Best
eye
(
PD
balance
)
adjustment.
(Refer
to
page
13.)
Step
3:Connect
the
servo
gain
adjuster.
(Refer
to
page
12.)
Step
4:Focus
gain
adjustment.
(Refer
to
page
13.)
Step
5:Tracking
gain
adjustment.
(Refer
to
page
13.)
Step
6:Focus
offset
adjustment
(Refer
to
page
14.)
Connection
of
Servo
Gain
Adjuster
Low-frequency
oscillator
©OOO
Servo
gain
adjuster
@
Ordinary
disc
@
Two-channel
oscilloscope
(with
trigger)
of
30MHz
or
over
@Low
frequency
oscillator
@
Conversion
connector(SZZP1032F)
Step
7:Tracking
offset
adjustment.
(Refer
to
page
14.)
Step
8:Tracking
offset
balance
adjustment.(Refer
to
page
14.)
Step
9:Disconnect
the
servo
gain
adjuster.
Step
10:PLL
adjustment.
(Refer
to
page
15.)
Step
11:
Check
of
play
operation
after
adjustment.
(Refer
to
page
15.)
(SZZP1017F)
GND
OSC
Oscillator
connection
terminals
@
ON/OFF
switch
@
C2
ON
.
GND
©
Selector
©)
;
osc
@
aoe
3
Oscilloscope
Oscilloscope
connection
wn)
O_O
terminals
we}
©
OO}
Tp2
TP3
TPI
CHI
ft?
f
¢
G
—12V
GND
+12V
(Main)
(Chassis)
(Main)
Conversion
connector
{SZZP1032F)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Technics SL-P200 and is the answer not in the manual?

Technics SL-P200 Specifications

General IconGeneral
BrandTechnics
ModelSL-P200
CategoryCD Player
LanguageEnglish

Related product manuals