IST-2137.EC03.01/E Istruzione / User’s Manual / Manuel d’utilisation Pag. 19/20
TECNOCONTROL S.r.l. - Via Miglioli, 47 20090 SEGRATE (MI) Tel. +39 02 26922890 - Fax +39 02 2133734
Tabella 8 / Table 8 / Tableau 8 SE137EH (Idrogeno Solforato / Hydrogen sulphide / Sulfure d'hydrogène)
“S1
-
SET”
(Dip-Switch)
Livelli Allarme (
Relé
)
Alarm levels(Relays) / Niveaux d'alarmes(Relais)
Ritardo dei Relé (
in Secondi
)
Relays Delay (Seconds) / retarde du relais (Secondes)
1
2
3
ALARM 1
ALARM 2
ALARM 3
ALARM 1
ALARM 2
ALARM 3
FAULT
OFF
OFF
OFF
5 ppm 10 ppm 20 ppm 12 30 60 30
ON
OFF
OFF
10 ppm 15 ppm 20 ppm 12 30 60 30
OFF
ON
OFF
10 ppm 20 ppm 30 ppm 12 30 60 30
ON
ON
OFF
Risevato
/ Reserved / Réservé
12 30 60 30
OFF
OFF
ON
TLV
-
TWA
(COSHH)
5 ppm
TLV
-
STEL
(COSHH)
10 ppm
TLV
-
C
20 ppm
0
0
0
30
ON
OFF
ON
TLV
-
TWA
(OSHA)
10 ppm
TLV
-
STEL
(OSHA)
15 ppm
TLV
-
C
50 ppm
0
0
0
30
OFF
ON
ON
Risevato
/ Reserved / Réservé
Risevato
/ Reserved / Réservé
ON
ON
ON
Risevato
/ Reserved / Réservé
Risevato
/ Reserved / Réservé
Tabella 9 / Table 9 / Tableau 9 SE137EHCN (Acido cianidrico / Hydrogen cyanide / Cyanure d'hydrogène)
“S1
-
SET”
(Dip-Switch)
Livelli Allarme (
Relé
)
Alarm levels(Relays) / Niveaux d'alarmes(Relais)
Ritardo dei Relé (
in Secondi
)
Relays Delay (Seconds) / retarde du relais (Secondes)
1
2
3
ALARM 1
ALARM 2
ALARM 3
ALARM 1
ALARM 2
ALARM 3
FAULT
OFF
OFF
OFF
1.0 ppm 2,5 ppm 5,0 ppm 12 30 60 30
ON
OFF
OFF
2,5 ppm 5,0 ppm 7,5 ppm 12 30 60 30
OFF
ON
OFF
3,0 ppm 6,0 ppm 9,0 ppm 12 30 60 30
ON
ON
OFF
5,0 ppm 10,0 ppm 10,0 ppm 12 30 60 30
OFF
OFF
ON
TLV
-
TWA
(
OSHA)
4.7 ppm
TLV
-
STEL
(COSHH)
10 ppm
TLV
-
C
(OSHA)
4,7 ppm
0
0
0
30
ON
OFF
ON
Risevato
/ Reserved / Réservé
Risevato
/ Reserved / Réservé
OFF
ON
ON
Risevato
/ Reserved / Réservé
Risevato
/ Reserved / Réservé
ON
ON
ON
Risevato
/ Reserved / Réservé
Risevato
/ Reserved / Réservé
Tabella 10 / Table 10 / Tableau 10 SE137EN (Ossido di azoto / Nitric oxide / Oxyde nitrique)
“S1
-
SET”
(Dip-Switch)
Livelli Allarme (
Relé
)
Alarm levels(Relays) / Niveaux d'alarmes(Relais)
Ritardo dei Relé (
in Secondi
)
Relays Delay (Seconds) / retarde du relais (Secondes)
1
2
3
ALARM 1
ALARM 2
ALARM 3
ALARM 1
ALARM 2
ALARM 3
FAULT
OFF
OFF
OFF
25 ppm 50 ppm 100 ppm 12 30 60 30
ON
OFF
OFF
25 ppm 50 ppm 75 ppm 12 30 60 30
OFF
ON
OFF
15 ppm 25 ppm 50 ppm 12 30 60 30
ON
ON
OFF
15 ppm 35 ppm 60 ppm 12 30 60 30
OFF
OFF
ON
TLV
-
TWA
(OSHA)
25 ppm
TLV
-
STEL
(OSHA)
25 ppm
TLV
-
C
(OSHA)
50 ppm
0
0
0
30
ON
OFF
ON
Risevato
/ Reserved / Réservé
Risevato
/ Reserved / Réservé
OFF
ON
ON
Risevato
/ Reserved / Réservé
Risevato
/ Reserved / Réservé
ON
ON
ON
Risevato
/ Reserved / Réservé
Risevato
/
Reserved / Réservé
Tabella 11 / Table 11 / Tableau 11 SE137EN2 (Biossido di azoto / Dioxyde d’azote / Dioxyde d’azote)
“S1
-
SET”
(Dip-Switch)
Livelli Allarme (
Relé
)
Alarm levels(Relays) / Niveaux d'alarmes(Relais)
Ritardo dei Relé (
in Secondi
)
Relays Delay (Seconds) / retarde du relais (Secondes)
1
2
3
ALARM 1
ALARM 2
ALARM 3
ALARM 1
ALARM 2
ALARM 3
FAULT
OFF
OFF
OFF
5,0 ppm 10,0 ppm 15,0 ppm 12 30 60 30
ON
OFF
OFF
3,5 ppm 7,5 ppm 15,0 ppm 12 30 60 30
OFF
ON
OFF
7,5 ppm 10,0 ppm 15,0 ppm 12 30 60 30
ON
ON
OFF
5,0 ppm 7,5 ppm 12,5 ppm 12 30 60 30
OFF
OFF
ON
TLV
-
TWA
(OSHA)
3.0 ppm
TLV
-
STEL
C
(OSHA)
5.0 ppm
TLV
-
C
(OSHA)
15.0 ppm
0
0
0
30
ON
OFF
ON
Risevato
/ Reserved / Réservé
Risevato
/ Reserved / Réservé
OFF
ON
ON
Risevato
/ Re
served / Réservé
Risevato
/ Reserved / Réservé
ON
ON
ON
Risevato
/ Reserved / Réservé
Risevato
/ Reserved / Réservé
Tabella 12 / Table 12 / Tableau 12 SE137EHCL (Acido cloridrico / Hydrogen Chloride / Acide chlorhydrique)
“S1
-
SET”
(Dip-Switch)
Livelli Allarme (
Relé
)
Alarm levels(Relays) / Niveaux d'alarmes(Relais)
Ritardo dei Relé (
in Secondi
)
Relays Delay (Seconds) / retarde du relais (Secondes)
1
2
3
ALARM 1
ALARM 2
ALARM 3
ALARM 1
ALARM 2
ALARM 3
FAULT
OFF
OFF
OFF
1,0 ppm 2,0 ppm 3,0 ppm 12 30 60 30
ON
OFF
OFF
1,0 ppm 2,5 ppm 5,0 ppm 12 30 60 30
OFF
ON
OFF
2,0 ppm 4,0 ppm 6,0 ppm 12 30 60 30
ON
ON
OFF
2,0 ppm 5,0 ppm 5,0 ppm 12 30 60 30
OFF
OFF
ON
TLV
-
TWA
(COSHH)
1.0 ppm
TLV
-
STEL
C
(COSHH)
5.0 ppm
TLV
-
C
(OSHA)
5.0 ppm
0
0
0
30
ON
OFF
ON
Risevato
/ Reserved
/ Réservé
Risevato
/ Reserved / Réservé
OFF
ON
ON
Risevato
/ Re
served / Réservé
Risevato
/ Reserved / Réservé
ON
ON
ON
Risevato
/ Reserved / Réservé
Risevato
/ Reserved / Réservé