EasyManua.ls Logo

Technogel MIXTRONIC 60 - Water Connection

Technogel MIXTRONIC 60
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
Water connection
The refrigerating system has a water-cooled connection; this water, which is connected parallel also goes to
the tap for washing.
Connect the mains hose to the pipe fitting that reads “ WATER IN”; the drain hose must be connected to the
fitting that reads “WATER OUT”.
The serial plates and inlet and outlet pipe fittings are found at the bottom back left hand side. If, for any
reason the serial plates indicating the inlet and outlet pipe fittings are missing or are illegible, please note that
the inlet pipe fitting is the lower one (and is connected to the pressure-switch valve inside the machine).
To connect the machine to the mains, we recommend using a rubber hose suitable for up to 150 Psi. (10
BAR).
WATER PRESSURE AND CONSUMPTION
If the machine is using mains water, check that the incoming water has a pressure of at least 25 Psi. (1,5
BAR).
If the water pressure is more than 70 Psi. (5 BAR), fit a pressure reducer to the system, to reduce this to 58
Psi. (4 BAR).
Average water consumption (when the refrigerating unit is on) is:
- MIXTRONIC 60 = 250/320 litres/hour* - 60/70 US Gal./hour*
* depending on the temperature of the incoming water
MIXTRONIC 110 = 380/480 litres/hour* - 100/105 US Gal./hour*
* depending on the temperature of the incoming water
If the water contains impurities, fit a purifying filter to prevent scaling and/or damage to the
pressure-switch valve.