Self-diagnosis system
The machine is fitted with a self-diagnosis system: should there be any problem in operation this will be
displayed with a 2-figure number. The table below lists the faults covered by the self-diagnosis system to
assist in trouble-shooting.
THE ALARM CODES ARE DISPLAYED IN THIS DISPLAY
Alarm code explanations:
01 probe 1 fault
02 probe 2 fault
fault in card (clock not operating – infinite time pause)
04 intervention of safety thermostat
05 intervention low pressure switch
06 intervention high pressure switch
07 intervention heat compressor
08 not assigned (signal processed only with machine on stop)
09 intervention heat device speed 1
10 intervention heat device speed 2
11 cover open
12 not assigned
Alarm correspondence – pin of connector J3:
code 04 pin 1
code 05 pin 2
code 06 pin 3
code 07 pin 4
code 08 pin 5
code 09 pin 6
code 10 pin 7
code 11 pin 8
0 volt pin 9
+12 volt pin 10