PRELIMINARY OPERATIONS, WASHING AND SANITIZATION
Before starting the machine it is necessary to wash and sanitize all the parts which come into contact with the
product.
WASHING AND SANITIZING MUST ALWAYS BE CAREFULLY AND SCRUPULOSLY
PERFORMED AT ANY START UP, BEFORE ANY NEW LOADING AND AFTER THE LAST
LOADING CYCLE IN ORDER TO COMPLY WITH ALL CURRENT HYGIENE LAWS AND
REGULATIONS.
Preliminary cleanout
Before starting the washing operations make sure the machine is unplugged.
1) Open the lid and rinse the tank with hot water at a temperature of 50°:60° C and then drain off
.
2) Heat the water in the tank to 50°C.
3) Add the detergent e.g. (for example DIVER SEY SU891 available in Italy or DIVER SEY
VK3L available in other countries) using a concentration of the product between
5 10%.
4) Plug in the unit and Turn on the stirrer for a few minutes. Unplug it again.
5) Wash carefully using a sponge and NON-ABRASIVE materials.
6) Disassemble the machine by removing the moving parts