PROVASET T3LPF REV.20210610
91
2. Choose the CONFIGURE menu, then the SENSOR CALIBRATION menu and en-
ter the administrator's access code (password).
3. Pay attention to the message FOLLOW INSTRUCTIONS! ; consult the manual.
4. Press on the message area to open the calibration page.
5. Select the calibration menu "FLOW"
6. 
A.
test range, resolution at least 0.01 litre/minute, accuracy at least 1 % FS.
-

10% are allowed.
          -
trolled by the electronic test pressure regulator.

804
0.00
l/min
FLOW
Read A/D bits
Reading
CALIBRATE
ZERO
CALIBRATE
GAIN
11.2.1 
804
0.00
804
l/min
FLOW
Read A/D bits
Saved A/D bits
Reading
CALIBRATE
ZERO

• 
Alternatively, seal the pipe at the TEST output;