INSTRUCTIONS FOR THE INSTALLATION,
USE AND MAINTENANCE OF
TECNICOMAR SYSTEM FOR SEWAGE WATER TREATMENT
MODEL: ECOmar 20 S; 32 S; 45 S; 70 S; 145 S.
S
Image for illustration purposes only
Rev.
Date
Main content revisions
00
10.02.2019
Main Unit
H
2
O
2
Dosing
System
Sea
Water
Pump
Filling
Pump
H
2
O
2
Dosing
System
ECOFLOC
Dosing
System
UV Sterilization
Unit
Sludge
Valve

Table of Contents

Questions and Answers

  • L
    Lori WallerAug 18, 2025
    Why does my TECNICOMAR ECOmar 145 S Water Dispenser system shut down for OVERLOAD ALARM fault?
    • C
      Christopher WattsAug 18, 2025
      The TECNICOMAR Water Dispenser system might shut down due to an overload alarm for several reasons: 1. The black switch button of the circuit switch breakers may be wrongly set. Ensure it is in the ON position, pressed inside the switch circuit breaker. 2. Circuit switch breakers keep tripping, indicating a system short circuit that needs to be resolved. 3. The power supply voltage may be incorrect. Power the plant with a voltage suitable to that indicated on the system nameplate, or replace the ECOmar S STP with one suitable for the power supply line voltage. 4. A broken control box can also cause this issue; in this case, it should be repaired or replaced.
  • T
    tiffanyschmidtAug 20, 2025
    Why does my TECNICOMAR ECOmar 145 S system shut down for FILLING ALARM fault?
    • T
      Taylor CollinsAug 21, 2025
      The system may shut down due to a filling alarm fault because of: 1. A malfunctioning Min. Level Sensor of the Treatment Tank. To resolve this, clean the level sensor and reinstall it. 2. Malfunctioning Filling Pump. Open all the valves installed along each filling pump suction / delivery piping. 3. A broken control box. If this is the case, repair or replace the main control box.
  • M
    Mary BrownAug 23, 2025
    Why does my TECNICOMAR ECOmar 145 S system shut down for SEAWATER ALARM fault?
    • L
      Leah JimenezAug 23, 2025
      The TECNICOMAR Water Dispenser system might shut down due to a seawater alarm fault for these reasons: 1. A malfunctioning Max. Level Sensor of the Treatment Tank. Clean the level sensor and re-install it. 2. A malfunctioning Seawater Pump. Open all the valves installed along seawater pump suction piping. 3. A broken control box. If this is the problem, repair or replace the main control box.
  • A
    Angela HallAug 26, 2025
    What to do if TECNICOMAR Water Dispenser has excessive noise and vibrations?
    • T
      trevorgarciaAug 26, 2025
      If your TECNICOMAR Water Dispenser is exhibiting excessive noise and vibrations, consider the following: 1. **System pulsation**: Check the Filling /Seawater pump correct priming and the presence of any leaks or restrictions on their suction piping, and correct it. 2. **Worn seals**: Replace pumps (filling, seawater, macerating) seals. 3. **Air presence**: Pressurize the affected circuit (filling, seawater, sludge discharge, clarified water discharge), by filling it activating the relative pump. This will help to eliminate the infiltrated air.
  • E
    ericmccartyAug 28, 2025
    Why does my TECNICOMAR ECOmar 145 S Water Dispenser system shut down for HIGH PRESSURE ALARM fault?
    • J
      Joseph MedinaAug 28, 2025
      The TECNICOMAR Water Dispenser system may shut down due to a high-pressure alarm fault due to: 1. Wrong settings of the black switch button of the circuit switch breakers. Set the black switch button of the circuit switch breakers, in ON position, with the switch button pressed inside the switch circuit breaker. 2. Wrong or inefficient ventilation of the treatment tank. Remove any obstructions from the air relief and vent line, ensuring they are as free as possible. 3. A broken control box. If this is the case, repair or replace the main control box.
  • A
    Angela TorresAug 30, 2025
    What to do if my TECNICOMAR Water Dispenser treated and discharged water are dark?
    • S
      Steve WilliamsAug 30, 2025
      If the treated and discharged water from your TECNICOMAR Water Dispenser is dark, check the following: 1. **H2O Dosing System**: Set the Dosing Timer parameter and the dosing pump flow regulation to the correct values shown on the attached Test Report. 2. **Safe filter**: If necessary, empty and clean the bag cartridge or replace it. 3. **Discharge Timer parameter**: Adjust the Discharge Timer parameter setting value according to the plant on board installation condition.
  • C
    Cindy AlexanderSep 2, 2025
    What to do if TECNICOMAR ECOmar 145 S Water Dispenser unit is powered correctly but does not start?
    • V
      Vickie CarlsonSep 2, 2025
      If the TECNICOMAR Water Dispenser unit is powered correctly and set in automatic mode, with 'System Running' displayed, but it doesn't start, consider these potential issues: 1. **Collecting Tank Level Probes malfunctioning**: Ensure each supplied sensor is correctly installed and connected, referring to the attached connections diagrams. 2. **Level Probe Control Box malfunctioning**: Repair or replace each supplied level probe control box. 3. **Broken control box**: Repair or replace the main control box.
  • G
    gregory60Sep 4, 2025
    How to fix no or low quality visualization on the TECNICOMAR ECOmar S STP display?
    • H
      Hannah WashingtonSep 4, 2025
      If there is no or low-quality visualization on the display of your TECNICOMAR ECOmar S STP, consider the following: 1. **Display contrast calibration**: Re-calibrate the display contrast by acting on the trimmer P2 installed on the rear side of the P.C.B. PRO14. 2. **Display backlight settings**: Set properly the “Display Backlight Timer” parameter. 3. **Broken control box**: Repair or replace the main control box.
  • S
    stevenmorrisSep 7, 2025
    What to do if TECNICOMAR ECOmar 145 S Sludge Discharge Valve (V2) does not open or close?
    • J
      Jeremy TaylorSep 7, 2025
      If the Sludge Discharge Valve (V2) on your TECNICOMAR Water Dispenser does not open or close, it could be due to: 1. A malfunctioning Motorized valve. Set the rotation direction of the actuator to Y2. 2. A broken control box. If this is the cause, repair or replace the main control box.
  • S
    samanthataylorSep 9, 2025
    What to do if TECNICOMAR Water Dispenser Discharge Valve (V1) does not open or close?
    • L
      Lauren LyonsSep 9, 2025
      If the Discharge Valve (V1) on your TECNICOMAR Water Dispenser does not open or close, consider: 1. A malfunctioning Motorized valve. Set the rotation direction of the actuator to Y2. 2. A broken control box. If this is the cause, repair or replace the main control box.

Summary

6 SYSTEM DESCRIPTION

7 SAFETY INSTRUCTIONS

7.1 Important Safety Information

General safety guidelines and responsibilities for users and operators of the ECOmar S STP.

7.2 Instructions and Warnings

Covers warnings and instructions applicable to subsystem items and the entire ECOmar S STP.

7.5 Safety Instructions and Prevention

Provides essential safety precautions for system startup, operation, and maintenance.

7.6 Before Turning on

Lists essential checks for mechanical, electrical, and hydraulic systems before powering on.

7.7 Danger Informations

Lists safety labels and general precautions for handling dangerous situations and equipment.

8 INSTALLATION

9 PCB CONTROL PANEL - Functional Description

9.2 Automatic mode

Guide to operating the system in automatic mode, including starting, stopping, and status checks.

9.4 Alarms Description

Details the system's alarms, their causes, displays, and reset procedures.

10 FIRST START UP PROCEDURE

10.1 Start-up Procedure

Step-by-step guide for the initial startup of the ECOmar S STP, including checks and activations.

11 ROUTINE OPERATION

13 COMMON PROBLEMS AND TROUBLESHOOTING

13.1 Troubleshooting Table

A table detailing common symptoms, their possible causes, validation checks, and remedies.

14 MAINTENANCE INSTRUCTIONS

14.4 MAINTENANCE PLAN FOR SEWAGE TREATMENT PLANT ECOMAR S

A comprehensive schedule detailing routine and periodic maintenance tasks for the ECOmar S plant.

16 SPARE PARTS LISTS

TECNICOMAR ECOmar 145 S Specifications

General IconGeneral
CategoryWater Dispenser
ModelECOmar 145 S
BrandTECNICOMAR
TypeBottled Water Dispenser
Cooling SystemCompressor
Power Consumption (Heating)500 W
Voltage220-240 V
Frequency50/60 Hz
CertificationCE
MaterialPlastic
Capacity5 L