EasyManua.ls Logo

Tecnosystemi Blitz 510 DA - The Steam Boiler Does Not Heat

Default Icon
43 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
3.11 – The steam boiler does not heat
The Blitz Coffee and cappuccino machine is equipped with a 1000 cc
stainless steel boiler for making steam.
The following components (fig.37) control the operation of the boiler:
- Feeding solenoid valve
- Resistance (7)
- Pressure switch (2)
- Anti-recall valve (3)
- Safety valve (4)
- Auto-level probe (5)
- Electronic station (6)
fig.37