EasyManua.ls Logo

TECO E710-403-H3SF - Page 11

TECO E710-403-H3SF
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
2.3 Product specifications and wiring diagram (for standard S type)
2.3.1 General Specifications
ITEM Basic Specifications
Control mode
IM: V/F、V/F+PG(In development)、SLV、SV(In
development)
PM: SV(In development)、SLV
SRM(In develo
p
ment): PMA-S
y
RM-SLV、S
y
RM-SLV
Frequency
Frequency control
range 0.01~599Hz
starting torque 150%/3Hz(VF) , 150% / 0.5Hz (SLV)
Frequency setting
resolution
Digital references: 0.01Hz
Analog references: 0.06Hz/60Hz
Frequency setting
keypad:Set directly with▲▼ keys or the VR on the keypad
External Input Terminlas:
AI1、AI2 (0~10V / 2~10V / 0~20mA / 4~20mA) input
Multifunction input up/down function
Setting frequency by communication method.
Frequency limit
Lower and upper frequency limits
3 skip frequency settings.
Speed control
accuracy
V/F :±2~3%
SLV :± 1%
Run
Operation set
Keypad run, stop button
External terminals:
Multi- operation-mode2 / 3 wire selection
Jog operation
Run signal by communication method.
Main
Control
Features
V / F curve setting
18 fixed curves and one customized curve
Carrier frequency 2~16KHz (default value : 4kHz)
Acceleration and
deceleration
control
2 off Acc / dec time parameters.
4 off S curve parameters.
Multifunction input 29 functions (refer to description on group3)
Multifunction output 21 functions (refer to description on group3)
Multifunction
analog output
5 functions (refer to description on group4)
Main features
Overload Detection,16 preset speeds,Auto-run,Acc/Dec Switch (2
Stages),Main/Alt run Command select,Main/Alt Frequency
Command select,PID control, torque boost, V/F start Frequency,
Fault reset,
Display
LED
Display :parameter / parameter value / frequency / line speed / DC
voltage / output voltage / output current / PID feedback / input and
output terminal status / Heat sink temperature / Program Version /
Fault Log.
LED
Status Indicator
FWDREVSEQREF
Protective
Functions
Overload
Protection
The relays to protect the motor and the inverter. (150%/1min)
Over voltage ·220V: >410V ,380V: >820V
Under Voltage ·220V: <190V ,380V: <380V
Momentary Power
Loss Restart
Inverter auto-restart after a momentary power loss.
Stall Prevention Stall prevention for Acceleration/ Deceleration/ Operation.
Short-circuit output
terminal
Electronic Circuit Protection.
Ground fault Using current detector protection.
STO Functions Output quick break
Other protection
features
Protection for overheating of heat sink,The carrier frequency
decreasing with the temperature function,fault output,reverse

Related product manuals