6-29
Communication
Address
Parameter Name & Function Default Unit
Setting
Range
Control
Mode
RS232 RS485
Internal Position Command 18 - Pulse Number
Pn453
Please refer to Pn402
0 pulse
-131072
131072
Pi
5AEH
5AFH
0746H
0747H
Internal Position Command 18 - Move Speed
Pn454
Please refer to Pn403
0 rpm
0
3000
Pi 5ADH 0748H
Internal Position Command 19 -Rotation Number
Pn455
Please refer to Pn401
0 rev
-16000
16000
Pi 5B0H 0749H
Internal Position Command 19 - Pulse Number
Pn456
Please refer to Pn402
0 pulse
-131072
131072
Pi
5B2H
5B3H
074AH
074BH
Internal Position Command 19 - Move Speed
Pn457
Please refer to Pn403
0 rpm
0
3000
Pi 5B1H 074CH
Internal Position Command 20 -Rotation Number
Pn458
Please refer to Pn401
0 rev
-16000
16000
Pi 5B4H 074DH
Internal Position Command 20 - Pulse Number
Pn459
Please refer to Pn402
0 pulse
-131072
131072
Pi
5B6H
5B7H
074EH
074FH
Internal Position Command 20 - Move Speed
Pn460
Please refer to Pn403
0 rpm
0
3000
Pi 5B5H 0750H
Internal Position Command 21 -Rotation Number
Pn461
Please refer to Pn401
0 rev
-16000
16000
Pi 5B8H 0751H
Internal Position Command 21 - Pulse Number
Pn462
Please refer to Pn402
0 pulse
-131072
131072
Pi
5BAH
5BBH
0752H
0753H
Internal Position Command 21 - Move Speed
Pn463
Please refer to Pn403
0 rpm
0
3000
Pi 5B9H 0754H
Internal Position Command 22 -Rotation Number
Pn464
Please refer to Pn401
0 rev
-16000
16000
Pi 5BCH 0755H
Internal Position Command 22 - Pulse Number
Pn465
Please refer to Pn402
0 pulse
-131072
131072
Pi
5BEH
5BFH
0756H
0757H
Internal Position Command 22 - Move Speed
Pn466
Please refer to Pn403
0 rpm
0
3000
Pi 5BDH 0758H
Internal Position Command 23 -Rotation Number
Pn467
Please refer to Pn401
0 rev
-16000
16000
Pi 5C0H 0759H
Internal Position Command 23 - Pulse Number
Pn468
Please refer to Pn402
0 pulse
-131072
131072
Pi
5C2H
5C3H
075AH
075BH
Internal Position Command 23 - Move Speed
Pn469
Please refer to Pn403
0 rpm
0
3000
Pi 5C1H 075CH
Internal Position Command 24 -Rotation Number
Pn470
Please refer to Pn401
0 rev
-16000
16000
Pi 5C4H 075DH
Internal Position Command 24 - Pulse Number
Pn471
Please refer to Pn402
0 pulse
-131072
131072
Pi
5C6H
5C7H
075EH
075FH

Table of Contents