EasyManuals Logo

TECO JSDEP-15A Simplified Manual

TECO JSDEP-15A
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
44
Communicati
on
Address
Parameter
Name & Function Default
Unit
Setting
Range
Control
Mode
RS232
RS485
Speed command smooth accel/decel time
Constant.
Sn206
Set Sn205=1
to enable this function then set the time
period for the speed to rise to 63.2% of the full speed.
1 msec
1
10000
S 52BH
0206H
Speed command linear accel/decel time constant.
Sn207
Set Sn205=2
to enable this function then set the time
period for the speed to rise linearly to full speed.
100
50
Ratio Speed
Speed Command (%)
Speed Command
Sn207
Time (ms)
1 msec
1
50000
S 52CH
0207H

Table of Contents