6-12
Communication
Address
Parameter Name & Function Default Unit
Setting
Range
Control
Mode
RS232 RS485
Preset Speed Limit 2. ( Torque control mode)
Tn106
In Torque control, input contacts SPD1 and SPD2
can be used to select Preset speed limit 2. As
follows:
Input Contact SPD2 Input Contact SPD1
1 0
Note: Input contacts status “1” (ON) and “0”
(OFF)
Refer to 5-6-1 to set high or low input logic levels.
200 rpm
0
│
3000
T 527H 0106H
Preset Speed Limit 3. ( Torque control mode)
Tn107
In Torque control, input contacts SPD1 and SPD2
can be used to select Preset speed limit 3. As
follows:-
Input Contact SPD2 Input Contact SPD1
1 1
Note: Input contacts status “1” (ON) and “0”
(OFF)
Refer to 5-6-1 to set high or low input logic levels.
300 rpm
0
│
3000
T 528H 0107H
Torque output monitor value
Tn108
When the torque level in CW or CCW direction
become greater then this value setting, the output
contact INT operate.
0 %
0
│
300
ALL C30H 0108H
Analog Speed Limited Proportion Controller
Tn109
This function used for adjusted analog voltage
command compared with the slope of speed limit
command.
3000 rpm
100
│
4500
T C0DH 0109H
Torque command smooth accel/decel time
Constant
Tn110
Set Tn101=2 to enable this function.
Set the time period to rise to 63.2% of the full
torque.
Torque
Command (%)
Time (ms)
Tn110
100
50
Torque Command
63.2
0 msec
0
│
10000
T 520H 010AH