31
System Parameters 
Address 
Parameter
Name & Function  Default
Unit
Setting
Range
Mode
RS232
RS485
Control Mode selection 
Setting
Explanation 
0  Torque Control 
1  Speed Control 
2 
External Position Control (external pulse 
Command) 
3  External Position/Speed Control Switching 
4  Speed/Torque Control Switching 
5  External Position/Torque Control Switching
6 
Internal Position Control (internal position 
Command) 
7  Internal Position/Speed mode switching 
8  Internal Position/Torque mode switching 
9  Reserved 
★
● 
Cn001 
A  Internal/External Position switching 
2  X
0 
│ 
A 
ALL  510H
0001H
SON (Servo On) Input contact function 
Setting
Explanation 
0  Input Contact, Enables SON (Servo On). 
★
 
Cn002.0
1 
Input Contact has no function. 
(SON is enabled when Power on). 
0  X
0 
│ 
1 
CCWL & CWL Input contact function. 
Setting
Explanation 
0 
CCWL and CWL input contacts are able to 
control the drive inhibit of CCW and CW. 
Cn002.1
1 
CCWL & CWL input contacts are not able to 
control
 CCW and CW drive inhibit. CCW and 
CW drive inhibit is disable. 
1  X
0 
│ 
1 
ALL 
Auto Tuning 
Setting
Explanation 
0  Continuously Auto Tuning is Disable 
Cn002.2
1  Continuously Auto Tuning is Enabled. 
0  X
0 
│ 
1 
Pi 
Pe 
S 
EMC reset mode selection 
Setting
Explanation 
0 
Reset EMC signal is only available in Servo 
Off  condition  (SON  contact  is  open)  and 
reset AL-09 by ALRS signal.  
P.S.) It is NOT allow t
applied. 
★
 
Cn002.3
1 
When EMC status is released, AL-
reset  on  both  Servo  ON  and  Servo  OFF 
conditions.  
 
Attention! 
Ensure  that  the  speed  command  are 
removed before the alarm is reset to avoid 
motor unexpected start. 
0  X
0 
│ 
1 
ALL 
51DH