1. All electrical wiring must be installed in compliance with the safety requirements of the current
Australian Standards AS/NZS 3000 Wiring Rules.
2. The air conditioner must be installed by professional personnel and the Installation manual is used
only for the professional installation personnel! The installation specifications should be subject to
our after-sale service regulations.
3. All equipment must be installed in compliance with your local and national Electricity Authority
Rules and Regulations.
4. The product must be properly grounded at the time of installation or electrical shock may occur.
5. For all electrical work, select the appropriate cable sizes relevant to the model. Connect cables
tightly, and clamp them securely to prevent external forces from causing loose connections.
Improper electrical connections can overheat and cause fire, and may also cause shock.
6. All wiring must be properly arranged to ensure that the control board cover can be closed
properly. If the control board cover is not closed properly, it can lead to corrosion and cause the
connection points on the terminal to heat up, catch fire, or cause electrical shock.
7. Installation must be performed according to the installation instructions. Improper installation
may cause Refrigerant leakage, water leakage, electrical shock, or fire.
8. Do not connect other appliances to the same circuit. Use an independent circuit to supply power.
Improper or insufficient power supply can cause fire or electrical shock.
9. The installation site should be well-ventilated.
10. The sites for installing and maintaining an air conditioner using Refrigerant R32 should be free
from open fire or welding, smoking, drying oven or any other heat source higher than 548 which
easily produces open fire.
11. When installing an air conditioner, it is necessary to take appropriate anti-static measures such as
wear anti-static clothing and/or gloves.
12. It is necessary to choose the site convenient for installation or maintenance wherein the air inlets
and outlets of the indoor and outdoor units should be not surrounded by obstacles or close to any
heat source or combustible and/or explosive environment.
13. If the indoor unit suffers refrigerant leak during the installation, it is necessary to immediately turn
off the valve of the outdoor unit and all the personnel should go out till the refrigerant leaks
completely for 15 minutes. If the product is damaged, it is a must to carry such damaged product
back to the maintenance station and it is prohibited to weld the refrigerant pipe or conduct other
operations on the user's site.
14. It is necessary to choose the place where the inlet and outlet air of the indoor unit is even.
15. It is necessary to avoid the places where there are other electrical products, power switch plugs
and sockets, kitchen cabinet, bed, sofa and other valuables right under the lines on two sides of
the indoor unit.
16. When filling the combustible refrigerant, any of your rude operations may cause serious injury or
injuries to human body and objects.
INSTALLATION SERVICE PRECAUTIONS (R32)
A WARNINGS FOR PRODUCT INSTALLATION
19