INDOOR UNIT INSTALLATION
Before installing the indoor unit, refer to
the label on the product box to make sure
that the model number of the indoor unit
matches the model number of the outdoor
unit.
Select installation location before
installing the indoor unit, you must choose
an appropriate location. The following
guidelines will help you choose an
appropriate location for the unit.
Proper installation locations should
meet the following requirements
Good air circulation
Convenient drainage
Noise from the Outdoor unit will not
disturb other people
Firm and solid—the location will not
vibrate
Strong enough to support the weight of
the unit
The Indoor Unit should be located at
least one meter from all other electrical
devices (e.g., TV, radio, computer)
DO NOT install unit in the following
locations:
NOTE ABOUT WALL HOLE
PRIOR TO INSTALLATION
Near any source of heat, steam,
combustible gas or ignition sources
Near flammable items such as curtains
or clothing
Near any obstacle that might block air
circulation
Near the doorway
In a location subject to direct sunlight
If there is no fixed refrigerant piping:
While choosing a location, be aware that
you should leave ample room for a wall
hole for refrigerant piping, drainage pipe
and connection cables that connect the
indoor and outdoor units. The default
position for all piping is the right side of
the indoor unit (while facing the unit).
However, the unit can accommodate
piping to both the left or right.
Floor
Ceiling
13cm 13cm
250cm
20cm
Note: The information supplied to our knowledge is correct; however is subject to change
without notice, therefore before relying on any important matter, please carefully evaluate
its accuracy, completeness and relevance for the purpose.