CHAPTER 6 - TESTING THE PERSONAL CLIMBER
You can test the electronics inside Personal Climber by using test mode. In test mode, you can
adjust the tension of the drive belt, check the odometer reading, and test all the LEDs on the
console.
To enter test mode, turn the Personal Climber off, then press and hold the HR Control key while
turning it back on. All displays will light until you release the key.
In test mode, the red lights above and below the Progress Indicator fields show the state of the
Personal Climber’s various input/output signals:
Indicator Signal Normal
Elapsed Time Not used off
Calories Slack Switch on
Speed RPM sensor off -
Heart Rate/Level Polar signal off
Distance Not used off
Calories/Hour Not used off
The Elapsed Time field shows “PC,” indicating this is a Personal Climber; Calories shows the
version number of the Personal Climber’s internal software; Speed shows the state of the slack
switch (either “On” or “Off”).
While the climber is in test mode, some of the console keys have special functions:
Switch Display
Displays the odometer reading and RPM sensor data.
Press HR Control to return to the normal test mode
display.
Up Arrow
Loosens the belt. The belt tensioning motor runs for as
long as you hold the key down. Don’t loosen the belt
for too long, or you may tangle or unsnap the belt.
Down Arrow
Tightens the belt. The belt tensioning motor runs for as
long as you hold the key down.
Endurance
Tests each LED digit group, in turn. Press the key
again to go to the next group. Press Clear to return to
the normal test mode display.
Strength
Tests each LED segment, in turn. Press the key again
to go the next segment. Press HR Control to return to
the normal test mode display.
Manual or
HR Control
Clears special displays and returns to normal test mode
display.
Enter or
Fat Burning
Lights all display LEDs. Press HR Control to return
to the normal test mode display.
Clear
From normal display, ends test mode.