F EMPTY INTERNAL WATER CONTAINER
Under extreme (environmental) circumstances it may be necessary to empty the
internal water container regularly. When the internal water container is full the
K light will flash and the display shows E2. Touch any button to stop the
beeping. The unit will switch off automatically. To empty the water container do
the following:
Do not move the unit. Drastic movements can cause water leakage.
Switch off the unit and remove the plug from the wall outlet.
Place a pan or appropriate tray on the floor underneath the drain hole.
Remove the drain knob and rubber plug 8 from the drain tube and let the
water run out. (± 0.8 litres).
Replace the rubber plug 8 and the drain knob and switch on the unit. The
warning light
K should be off and E2 disappears.
G
NOTE!
When the air conditioner is in use, under normal circumstances the
condensed water will be drained through the air outlet-tube.
DEHUMIDIFICATION
If the unit will be used mainly as dehumidifier, do not connect the exhaust hose
9 and let the warm air return in the room. Continuous drainage is then necessary
and more efficient. You must, however, use a water drain tube, placing its
discharge end at a suitable drainage point.
G MAINTENANCE
G
WARNING!
Switch off the unit and remove the electrical plug from the mains
before cleaning the appliance or filter, or before replacing the filters.
Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol,
detergents or other cleansing solutions. For maintenance of the filters, refer to
Chapter D “Air Filter”.
G
NOTE!
Never use the air conditioner without screenfilter.
H STORAGE
Empty the internal water container (refer to Chapter F)